Every Shivi online UPS uses DSP-based double conversion with a high-frequency PWM inverter using IGBTs, so the load is protected against spikes, surges and brownouts. Choose your series to see the full specification.
Alpha Series Online UPS
Single-phase in, single-phase out. DSP-based double conversion with an in-built isolation transformer, a wide input voltage range and a high input power factor. Parallel redundancy is optional.
Standard features
Wide input voltage range
High input power factor
In-built isolation transformer
Protection against over voltage, short circuit and over temperature
Auto fan speed adjustment
LCD display monitoring all operation status
Optional features
Dry contacts
Battery cold start
Static bypass
Parallel redundancy
OfficesRetail countersLabs & clinicsSmall server rooms
Specification
Alpha · 1 – 15 kVA
Input
Nominal voltage
230 VAC
Voltage range
230 V ±20%
Frequency
50 Hz
Output
Voltage
220 / 230 / 240 V (selectable)
Voltage regulation
1%
Total harmonic distortion
2%
Power factor
0.9
Crest factor
3:1
Overload (inverter mode)
110% for 2 minutes
DC link
Battery voltage
120, 144, 180, 192 VDC
System
Efficiency (inverter)
Up to 92 – 95%
Display
LED + LCD
Ingress protection
IP20
Audible noise
50 dB
Environmental conditions
Operating temperature
0 – 40 °C
Storage temperature
−20 °C to 70 °C
Relative humidity
0 – 95% (non-condensing)
Maximum altitude
1000 m without derating
Specifications are indicative and may be customised. Request a datasheet for the exact ratings of your model.
Beta Series Online UPS
Three-phase in, single-phase out. In-built isolation transformer, auto re-transfer static switch and manual bypass for single-phase loads on a three-phase supply. Parallel redundancy is optional.
Standard features
High-frequency PWM using IGBTs
In-built isolation transformer
Auto re-transfer static switch
Manual bypass
Extended battery back-up
Optional features
Static bypass
Input power factor 0.99
Parallel redundancy
IT & data centresIndustriesCommercial establishmentsHospitalsBanks & financial institutionsTelecom
Specification
Beta · 5 – 100 kVA
Input
Nominal voltage
3Ø, 380 / 400 / 415 V
Voltage range
350 to 460 V
Frequency
50 Hz
Input power factor
0.99 (optional)
Output
Nominal voltage
220 / 230 / 240 V (selectable)
Frequency
50 Hz
Power factor
0.9
Voltage regulation
±1%
Voltage distortion
≤ 3%
Overload
110% for 2 minutes
Crest factor
3:1
Efficiency (inverter)
Up to 92 – 95%
DC link
Battery voltage
240 V, 360 VDC
Voltage tolerance
±1%
Voltage ripple
±1%
Static bypass (optional)
Switching time
Inverter failure: 2 ms · other modes: 0
General
Ingress protection
IP20
Audible noise at 1 m
< 60 dBA
Cooling
Forced air
Environmental conditions
Operating temperature
0 – 40 °C
Storage temperature
−20 °C to 70 °C
Relative humidity
0 – 95% (non-condensing)
Maximum altitude
1000 m without derating
Specifications are indicative and may be customised. Request a datasheet for the exact ratings of your model.
Gama Series Online UPS
Three-phase in and out for heavy loads. In-built isolation transformer, and energy saving mode, with 50 Hz or 60 Hz operation. Parallel redundancy is optional.
Standard features
High-frequency PWM using IGBTs
In-built isolation transformer
Auto re-transfer static switch
Energy saving mode
Protection against DC shoot-through fault
Optional features
Remote monitoring for alarms / indications
Remote emergency power off
Potential-free contacts for remote indications
Voltage stabiliser in bypass line
Parallel redundancy
Data centresIndustrial plantsHospitalsTelecomBanks & financial institutionsLarge commercial establishments
Specification
Gama · 5 – 300 kVA
Input
Nominal voltage
3Ø, 380 / 400 / 415 V
Voltage range
350 to 460 V
Frequency
50 Hz or 60 Hz (selectable)
Output
Nominal voltage
220 / 230 / 240 V (selectable)
Frequency
50 Hz or 60 Hz
Frequency synchronisation range
±1%
Power factor
0.9
Voltage regulation (balanced load)
±1%
Phase displacement (balanced load)
120° ±1%
Voltage distortion
≤ 3%
Overload
125% for 10 minutes
Crest factor
3:1
Efficiency (inverter)
Up to 93%
DC link
Battery voltage
360 V, 384 V
Voltage regulation
±1%
Voltage ripple
±1%
General
Ingress protection
IP20
Cooling
Forced air
Environmental conditions
Operating temperature
0 – 40 °C
Storage temperature
−20 °C to 70 °C
Relative humidity
95% (non-condensing)
Maximum altitude
1000 m without derating
Specifications are indicative and may be customised. Request a datasheet for the exact ratings of your model.
Compare Series
Alpha, Beta and Gama at a glance
Pick by your incoming supply and the kind of load you need to protect.
Specification
Alpha1 – 15 kVA
Beta5 – 100 kVA
Gama5 – 300 kVA
Configuration
1Ø in – 1Ø out
3Ø in – 1Ø out
3Ø in – 3Ø out
Rating
1 – 15 kVA
5 – 100 kVA
5 – 300 kVA
Input voltage
230 V ±20%
3Ø 380 / 400 / 415 V
3Ø 380 / 400 / 415 V
Input frequency
50 Hz
50 Hz
50 / 60 Hz (selectable)
Output voltage
220 / 230 / 240 V
220 / 230 / 240 V
220 / 230 / 240 V
Output power factor
0.9
0.9
0.9
Overload
110% for 2 min
110% for 2 min
125% for 10 min
Efficiency (inverter)
Up to 92 – 95%
Up to 92 – 95%
Up to 93%
Battery voltage
120 / 144 / 180 / 192 VDC
240 / 360 VDC
360 / 384 VDC
Isolation transformer
In-built
In-built
In-built
Static bypass
Optional
Optional · auto re-transfer switch
Auto re-transfer static switch
Parallel redundancy
Optional
Optional
Optional
Source: Shivi Electronics System product brochure. Specifications may be customised to your requirement.
Complete Power Range
Inverters, stabilizers, solar and batteries
Everything around your UPS, from one manufacturer. Tell us your load and we will share the exact ratings and pricing.
Sine Wave Inverters
Home, lift and commercial backup
FrontRear panel
Specifications on request
Pure sine wave backup power for sensitive electronics, with dedicated models for lifts and commercial loads.
Home sine wave inverterQuiet, appliance-safe power for fans, TVs and refrigerators.
Lift backup inverterBrings the lift to a safe floor when the mains fails.
Commercial sine wave inverterBackup for small offices, clinics and retail counters.